Abstract: | The use of composite materials in religious buildings and historical monuments, include two key principles,
supported by the Venice Chart (1964)namely: structural interventions are less visible and does not alter the appearance of
the building; action is reversible, with the possibility of disassembling initially established in the event of non performance.
Composite building efficiency is obtained only by ensuring adequate anchorage length at the ends of the material. |