DSpace at Transilvania University >
Mechanical Engineering >
CNSRT 2009 >
Please use this identifier to cite or link to this item:
http://hdl.handle.net/123456789/1360
|
Title: | EXPERIMENTAL DETERMINATION OF HEAT LOSSES FOR A BURIED TRANSPORT PIPELINE IN NON-ISOTHERMAL STATE |
Authors: | EPARU, C NEACSU, S RADULESCU, R ALBULESCU, M |
Keywords: | heat, oil, transport, non-isothermal, transducers |
Issue Date: | 2009 |
Publisher: | Transilvania University Press of Braşov |
Citation: | Google Scholar |
Series/Report no.: | CNSRT 2009;485-492 |
Abstract: | In the thermotechnics laboratory of the Petroleum – Gas
University of Ploiesti an experimental stand consisting of a 60 meter buried
pipeline was built. Sensors were placed to measure the temperature field
around the pipeline. In order to determine the heat loss over the entire length
of the pipeline a 3D model was created, model which was calibrated based
on experimental data. At the end of the paper the heat loss determined over
the entire length of the pipeline at different moments in time is presented. |
URI: | http://hdl.handle.net/123456789/1360 |
ISBN: | 978-973-598-521- 9 |
Appears in Collections: | CNSRT 2009
|